Products
Economy Vertical Centrifugal Pump
Flow Rate:3.6~240 m³/h
Head range:7.5~35 m
Motor power:0.75KW~30KW
Speed range: 2900r/min
Media temperature: ≤40℃
Insulation Class: F+
IP Rating: IP55+
Features
Base Configuration
| ➣2-pole Motor |
| ➣Cast Iron Pump Body |
| ➣E-coated & Cast Iron Impeller |
Products Overview
YD- Economy vertical centrifugal pump
YD Economy vertical centrifugal pump is a series product designed in accordance with the characteristics of single-stage single-suction pumps and domestic and international standards; it optimizes the hydraulicmodel to improve the efficiency of the water pump. Main features: Small size, lightweight, small footprint.Main advantages: Perfect structure, compactness, low noise, high efficiency, energy saving, firmness,durability, and convenient maintenance, etc. Suitable for conveying clear water at normal temperature, orthe liquids with physical and chemical properties similar to water; mainly applicable to the chiller.
Features
Advantage

Impeller Selection
Impellers of different materials are optional - improve corrosion resistance.

Pump Body
Adopts advanced casting technology - Enhanced pressure resistance and strength of the pump body

Space-Saving Design
A streamlined close-coupled shaft reduces the overall footprint for tighter installations.

Enhanced Cooling Tech
Our proprietary housing and fan cover design accelerates heat release for cooler motor runs.
Precautions
Before starting up and running the pump, turns the fan blades to check if they rotate smoothly withoutabnormal sounds. The pump is not allowed to be started before the pump is not filled with liquid or the air inthe pump body is completely drained.
1. Water injection of (pump)
Close the valve, loosen the air relief cock on the pump head and unscrew it to a certain degree to drainoff the air inside the pump body. It should be noted that the vent hole on the air relief cock should not pointto people, motor or other objects that are not suitable for contact with the liquid in the pipeline. Besides, theair relief cock should not be removed, especiall for the pump for pumping hot water or chemical agents.During this operation, pay more attention to avoiding the air relief cock pointing to people, motor or otherobjects that are not suitable for contact with the liquid in the pipeline in case of injury or damage.
Slowly open the valve until the liquid flows out of the vent hole evenly.
Tighten the air relief cock and fully open the valve.
2. Running
Before the pump starts, the inlet valve should be fully opened, and the outlet valve is slightly opened.
Start the pump and check the rotation direction. Slowly open the outlet valve to adjust the pump flow tothe required value.
Pay attention to the operation of the pump. If finding any abnormality, stop the pump in time for trouble-shooting.
Certifications



Sales And Service Network

Hot Tags: economy vertical centrifugal pump, YD pump, vertical centrifugal pump, chiller water pump, water circulation pump, centrifugal corrosion proof pump, centrifugal transfer system pump, centrifugal industrial booster system, centrifugal pumping system, centrifugal clean water pump, centrifugal electroplating pump